• Low-viscosity triple-proof paint:QLD5901、QLD590K、590P

Low-viscosity Triple-proof Paint:QLD5901、QLD590K、590P

Inquire Now

Description:

 

Low-viscosity triple-proof paint

u  Technical Data Table

Performance

5901

590K

590P

Appearances

Transparent

Transparent

Transparent

Main components

Deoxidised silica gel

Modified acrylic acid

Modified polyurethane

Solid content%

100

35

100

Densitiesg/mm3

1.0±0.1

1.0±0.1

1.0±0.1

Surface drying timemin

10~30

3~10

3~10

Full solidification time

25℃24h

80℃3min

80℃3min

Tensile strengthMPa

1.0

4.5

4.5

Tearing elongation%

100

30

100

Hardnessshore A

20

65

65

Shearing strengthMPa

1.0

2.5

2.5

Peeling strengthN/mm

6

6

6

Dielectric strengthkv/mm

25

50

50

Dielectric constant1.2MHz

3.0

2.7

2.7

Loss factor1.2MHz

0.005

0.002

0.002

Volume resistanceΩ·cm25℃

2.0×1014

1.0×1014

1.0×1014

Working temperature range

-50~250

-50~150

-50~150

u  Features and Uses 

This product is a low viscosity neutral polymer composite material, single-component, easy to spray, dip coating and brush coating. It has good resistance to high and low temperatures; after curing into a transparent protective film, it has superior insulation, moisture-proof, leakage-proof, shock-proof, dust-proof, corrosion-proof, anti-aging, corona-resistant and other properties. Widely used in electronic components surface coating protection.

u  Typical Applications

5901 Organic Silicon Triple Anti Varnish: Deoxidising silica gel, used for coating protection of LED electronic components, is not suitable for copper and PC materials.

590K Acrylic Triple Defence Paint: Modified acrylic, free of silicone, ketone, phenol and other materials, blue colour under UV light, easy to detect.

590P polyurethane triple-proof paint: Modified polyurethane, free of silicone, ketone and phenol, blue colour under UV light, easy to detect.

u  Operation process

      1. Load the glue into the dipping bucket for dip coating, the circuit board or components should not be immersed too fast to avoid air bubbles.

      2. When spraying, fill the spray bottle with adhesive solution and spray. Use thinner to clean the spray bottle after spraying.

 

      3. If the viscosity of the glue is thick, diluent can be used to dilute. When a large amount of glue viscosity is low, the thickness of the coating is thin; on the contrary, the viscosity of the glue is high, the thickness of the coating thick. The amount of thinner is recommended to be 20~40%.

u  Notes

1. Unused glue should be sealed and stored. When used again, if there is crust on the seal or surface, remove it, which will not affect the normal use.

2. The construction site should be well-ventilated.

      3. Cool and dry place sealed storage for 6 months. After the expiry of the test, it can still be used.